marca:
ACEYArtículo No.:
ACEY-BP32-500A800Aconformidad:
CE Certifiedgarantía:
One Year warranty with lifetime supportOrden (Moq) :
1pago:
T/Torigen del producto:
China1-32 Series 500A Charge 800A Discharge Lithium Battery Protection Board BMS Tester
Product Description
1-32 series 500A Charge 800A discharge bms tester with high degree of automation, fast testing speed and high testing accuracy. It is used to test functions of BMS of MCN battery, LiFeO4 battery and cobalt acid battery. The main testing items include overcharge protection, overcharge recovery, overdischarge protection, overdischarge recovery, overcurrent protection (overcharge current and overdischarge current), internal resistance, self-consumption, short circuit protection, overcharge protection time, overcurrent protection time, overdischarge protection Time, balance current, balance voltage etc.
battery management system test equipment is required to be connected to a computer, th system generally requires an XP system, the interface of tester and computer is RS232.
Parameter
(1)Input power supply: 180~240V 50/60HZ,Power: 5000W
(2)Power standard supply: AC 220V/50HZ,Range:±10%
(3)The voltage of chare and discharge:5000mV ~160000mV
(4)It can test and set the voltage range when this machine is charging and dischagring..
(5)Current accuracy::±(0.1%FS+0.1%RD)
(6)Voltage accuracy±(0.1%FS+0.1%RD)
(7)Current resolution:1mA (smallest unit)
(8)Voltage resolution:1mV (smallest unit)
(9)Cycles:1~9999
(10)With log function, including operation records and exception records during the whole process of testing, which can be used for traceability of the testing process.
(11)Data processing, human-machine interface
(12)Export data formation:Excel
(13)Interface:RS232
(14)Accuracy calibration/software calibration
(15)With scan code start function
(16)MES system connection
Test Functions
No. | Function | Range | Accuracy | unit |
1 | Self-consumption of single cell | 0--500 | ±0.1 | uA |
2 | Self-consumption | 0--5000 | ±1 | uA |
3 | Overcharge voltage | 500--5000 | ±1 | mV |
4 | Overcharge recovery voltage | 500--5000 | ±1 | mV |
5 | Overcharge voltage protection delay | 0--10000 | ±1 | mS |
6 | Overdischarge voltage | 500--5000 | ±1 | mV |
7 | Overdischarge recovery voltage | 500--5000 | ±1 | mV |
8 | Overdischarge voltage protection delay | 0--10000 | ±1 | mS |
9 | Overcharge protection current protection value | 0.1--500 | ±0.01 | A |
10 | Overcharge protection current protection delay | 0--20000 | ±1 | mS |
11 | Overdischarge protection current protection value | 0.1--800 | ±0.01 | A |
12 | Overdischarge protection current protection delay | 0.1--20000 | ±1 | mS |
13 | Equalization function | 500--5000 | ±1 | mV |
opening voltage | ||||
14 | Equalizing current | 1--500 | ±1 | mA |
15 | Charging current | 0.1--200 | ±0.01 | A |
16 | Discharging current | 0.1--200 | ±0.01 | A |
17 | Charging time | 0--30 | ±1 | S |
18 | Discharging time | 0--60 | ±1 | S |
19 | The difference of single cell self-consume | 0-500 | ±0.1 | uA |
20 | Resistance | 0-999 | ±1 | mΏ |
21 | Tiempo de protección contra cortocircuitos | 0-5000 | ±1 | a nosotros |
22 | El voltaje de carga de una sola celda. | 500--5000 | ±1 | mV |
23 | El voltaje de descarga de una sola celda. | 500--5000 | ±1 | mV |
24 | Abra el circuito de voltaje | 102000 | ±1 | mV |
25 | Número de análogos de voltaje | 32 | 0 | piezas |
Pantalla del producto